First Ever Hybrid Procedure of Balloon Co-arctoplasty & Patent Ductus Arteriosus (PDA) Ligation in a Neonate in Bangladesh

Authors

  • Nurun Nahar Fatema Pediatric Interventional Cardiologist, Bangladesh
  • Md Shaukat Cardiovascular and Thoracic Surgeon, Bangladesh
  • Ashik Md Raihan Chowdhury Registrar, Pediatric Cardiology, Bangladesh

Keywords:

Hybrid Procedure, Balloon Co-arctoplasty

Abstract

Coarctation of the aorta is a rare form of congenital heart disease, though preductal co-arctation is not very uncommon. This is a report on a 28-day-old girl who was referred to our center for evaluation. Doppler echocardiography showed severe preductal coarctation of aorta and a small-sized Patent Ductus Arteriosus (PDA). Later, it was confirmed by aortogram which showed critical coarctation of aorta (COA) with a very large Patent Ductus Arteosus (PDA). This full-term infant with symptomatic COA and a large PDA was treated successfully with a hybrid procedure of Balloon angioplasty and PDA ligation.

Bangladesh Heart Journal 2023; 38(1): 88-91 

Abstract
168
PDF
266

Downloads

Published

2023-07-08

How to Cite

First Ever Hybrid Procedure of Balloon Co-arctoplasty & Patent Ductus Arteriosus (PDA) Ligation in a Neonate in Bangladesh. (2023). Bangladesh Heart Journal, 38(1), 88-91. https://doi.org/10.3329/bhj.v38i1.67223