Intrarater Reliability of Chest Expansion using Cloth Tape Measure Technique

Authors

  • Vikram Mohan MPT. Department of Physiotherapy, Faculty of Health Sciences, UniversitiTeknologi MARA, PuncakAlam, Selangor
  • Nurul Hafizah Dzulkifli BPT. Department of Physiotherapy, Faculty of Health Sciences, UniversitiTeknologi MARA, PuncakAlam, Selangor
  • Maria Justine Department of Physiotherapy, Faculty of Health Sciences, UniversitiTeknologi MARA, PuncakAlam, Selangor
  • Rohani Haron Department of Physiotherapy, Faculty of Health Sciences, UniversitiTeknologi MARA, PuncakAlam, Selangor
  • Leonard Joseph H MSPT. Physiotherapy Program, Faculty of Allied Health Sciences, UniversitiKebangsaan Malaysia, Kuala Lumpur
  • Chandrasekar Rathinam MPT. Physiotherapy department, Ida Darwin, Fulbourn, Cambridge

DOI:

https://doi.org/10.3329/bjms.v11i4.12602

Keywords:

intrarater reliability, chest expansion, axillary, fourth intercostals, xiphoid

Abstract

Objective: The Objective of this study was to determine the intrarater reliability of chest expansion at three different anatomical landmarks using a cloth tape measure among healthy peoples.

Materials and Methods: 120 healthy male and female volunteers were evaluated on two occasions in different days. The measures   consisted of chest expansion measurement at axilla, fourth intercostals and xiphoid levels. The measurements   were taken in the standing position with the arms hanging sideways at all the three different anatomical landmarks. The test-retest reliability of the measurements was determined by intraclass correlation coefficient (ICC) and standard error of measurements (SEMs).

Results: An acceptable reliability was determined  by ICC values greater than than 0.85 and SEMs less than 5%. The mean age of the subjects was 21.93 years. ICC of all measures ranged between 0.95 to 0.97 and SEMs were 1.9%, 1.8%, 1.5% at the axillary, fourth intercostals and xiphoid level respectively.

Conclusions: The findings of this study suggested that, the cloth   tape measurement was reliable at all the three different anatomical landmarks of the chest wall. Therefore, this measurement technique could be used as an outcome measure for chest expansion in the management   of cardiorespiratory conditions.

DOI: http://dx.doi.org/10.3329/bjms.v11i4.12602

Bangladesh Journal of Medical Science Vol. 11 No. 04 Oct12

Downloads

Download data is not yet available.
Abstract
674
PDF
358

Downloads

Published

2012-11-13

How to Cite

Mohan, V., Dzulkifli, N. H., Justine, M., Haron, R., Joseph H, L., & Rathinam, C. (2012). Intrarater Reliability of Chest Expansion using Cloth Tape Measure Technique. Bangladesh Journal of Medical Science, 11(4), 307–311. https://doi.org/10.3329/bjms.v11i4.12602

Issue

Section

Original Articles