Efficacy of Sonoelastography Images in Solitary Cold Thyroid Nodule and Compared with Fine Needle Aspiration Cytology Findings (FNAC)

Authors

  • Jasmin Ferdous Senior Medical Officer. Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Mahbub ur Rahman Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Hosne Ara Rahman Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Jamiul Hossain Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Samira Sharmin Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Farida Yasmin Institute of Nuclear Medicine and Allied Sciences, Mitford, Dhaka
  • Jhorna Das Institute of Nuclear Medicine and Allied Sciences, Khulna
  • Moazzem Hossain National Institute of Ophthalmology, Dhaka
  • Sharmin Akther Apollo Hospital, Dhaka

DOI:

https://doi.org/10.3329/bjnm.v19i2.35914

Keywords:

Elastrography, Thyroid Nodule, Radionuclide Scan

Abstract

Objective: To evaluate the validity of sonoelastography of cold thyroid nodule in diagnosis of malignant nodule with fine needle aspiration cytology analysis as the reference standard.

Patients and Methods: This cross sectional study was conducted in the Institute of Nuclear Medicine & Allied Sciences (INMAS), Sir Salimullah Medical College (SMC) & Mitford Hospital campus, Dhaka, from July 2015 to June 2016 in 85 patients with solitary solid cold nodule.  Eighty five nodules in these patients were examined by conventional ultrasound, ultrasound elastography and radionuclidescan. The final diagnosis was obtained from cytological findings. Tissue stiffness on ultrasound elastography was scored from 1 (low stiffness over the entire nodule) to 4 (high stiffness over the entire nodule).

Results: The mean age was found 33.8±10.1 years with range from 12 to 58 years and male to female ratio was 1:5.1. The mean size of nodules was found 2.0±0.6 cm. Most (40.0%) of the patients were found in elastography score 2, 22(25.9%) score 1, 17(20.0%) score 4 and 12(14.1%) score 3. The validity of elastography scores had sensitivity 77.8%, specificity 86.2%, accuracy 83.5%, positive predictive values 72.4% and negative predictive values 89.3% for prediction of thyroid nodule.

Conclusion: Considering the validity parameter the elastography may be effective diagnostic modality for evaluation of thyroid nodule.

Bangladesh J. Nuclear Med. 19(2): 103-106, July 2016

Downloads

Download data is not yet available.
Abstract
20
PDF
52

Downloads

Published

2018-03-19

How to Cite

Ferdous, J., Rahman, M. ur, Rahman, H. A., Hossain, J., Sharmin, S., Yasmin, F., Das, J., Hossain, M., & Akther, S. (2018). Efficacy of Sonoelastography Images in Solitary Cold Thyroid Nodule and Compared with Fine Needle Aspiration Cytology Findings (FNAC). Bangladesh Journal of Nuclear Medicine, 19(2), 103–106. https://doi.org/10.3329/bjnm.v19i2.35914