Diagnostic Test Validity of MCV for Determination of Thalassaemia Carrier in Bangladesh

Authors

  • Nazmul Haque Assistant Professor, Department of Paediatric Neurology, National Institute of Neurosciences & Hospital, Dhaka
  • Narayan Chandra Saha Professor & Head, Department of Paediatric Neurology, National Institute of Neurosciences & Hospital, Dhaka
  • Mohammad Ekhlasur Rahman Former Head, Department of Paediatrics, Dhaka Medical College, Dhaka
  • Tahmina Ahmed Junior Consultant (Gynaecology), Kurmitola General Hospital, Dhaka

DOI:

https://doi.org/10.3329/jninb.v2i2.34103

Keywords:

Diagnostic test, validity, mean corpuscular volume, mean corpuscular haemoglobin

Abstract

Background: Mean corpuscular volume (MCV) and mean corpuscular haemoglobin (MCH) of red blood cell is the useful diagnostic test which is performed during routine blood examination.

Objective: The purpose of the present study was to measure the diagnostic test validity of MCV for the determination of thalassaemia carrier.

Methodology: This analytic cross-sectional study was carried out in the Department of Pediatrics and Department of Medicine at MAG Osmani Medical College Hospital, Sylhet, Bangladesh from September 2007 to January 2009 for a period of one year and five months. Siblings and cousins of beta Thalassemia major and Hb- E -beta Thalassemia satisfying the selection criteria were enrolled. The detailed history and thorough physical examination were done meticulously. Five (5) mL blood was drawn from each case and control for determination of MCV and Hb-Electrophoresis.

Result: Total 63 were enrolled as cases and total 65 were enrolled as controls. Sensitivity, specificity, positive and negative predictive value of MCV in determination of thalassemic carriers were 92%, 89.2%, 89.2% and 92% respectively. The area under the curve value was 0.094 (0.035 to 0.152).

Conclusion: In conclusion the diagnostic test validity of MCH and MCH is high in determination of Thalassemic carrier.

Journal of National Institute of Neurosciences Bangladesh, 2016;2(2): 94-97]

Downloads

Download data is not yet available.
Abstract
2
PDF
2

Downloads

Published

2017-10-22

How to Cite

Haque, N., Saha, N. C., Rahman, M. E., & Ahmed, T. (2017). Diagnostic Test Validity of MCV for Determination of Thalassaemia Carrier in Bangladesh. Journal of National Institute of Neurosciences Bangladesh, 2(2), 94–97. https://doi.org/10.3329/jninb.v2i2.34103

Issue

Section

Original Research Articles