Sequential Dilatation of Endovascular Stent in Coarctation of Aorta: Follow-up Case Report
DOI:
https://doi.org/10.3329/cardio.v17i1.80002Keywords:
Coarctation of aorta, endovascular stentAbstract
A 2.6-year-old girl weighing 10kg was diagnosed as Severe Coarctation of Aorta in October 2008. Subsequently, she underwent Balloon angioplasty in April 2009 & later stenting of coarct area was performed with a covered stent in April 2014. In January 2024 she came for follow up after a long gap and re-coarctation was noticed in echocardiography. Balloon dilatation of the covered stent was performed with a 16 × 40 mm Z-med balloon successfully at 17 years of age. Successful journey of this patient since her first admission to pediatric ICU till today led us to write this report.
Cardiovasc j 2024; 17(1): 45-47
Downloads
38
22