Modification of Frozen Elephant Trunk Technique for Acute Type-A Aortic Dissection - A Case Report

Authors

  • Saikat Das Gupta Department of Cardiac Surgery, Square Hospitals Limited, Dhaka, Bangladesh
  • PK Chanda Department of Cardiac Surgery, Square Hospitals Limited, Dhaka, Bangladesh
  • DK Adhikary Department of Cardiology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh

DOI:

https://doi.org/10.3329/uhj.v18i1.57884

Keywords:

ECG, CAG

Abstract

Acute type-A aortic dissection (ATAAD) is a dreadfully fatal cardiovascular emergency. The mortality rate among medically treated patients is 50% within two days. Surgery is the gold standard and urgent surgical treatment is indicated for all patients, except for those who are moribund or severely comorbid. However, early mortality after operation remains high (9–25%). We hereby present a case of 22 years young, male, Marfan patient with a family history of ATAAD treated successfully by us at Square Hospital Ltd by modified Bentall’s procedure with total arch replacement with Frozen Elephant Trunk (FET) technique.

University Heart Journal 2022; 18(1): 65-70

Downloads

Download data is not yet available.
Abstract
17
PDF
38

Downloads

Published

2022-01-31

How to Cite

Gupta, S. D. ., Chanda, P., & Adhikary, D. (2022). Modification of Frozen Elephant Trunk Technique for Acute Type-A Aortic Dissection - A Case Report. University Heart Journal, 18(1), 65–70. https://doi.org/10.3329/uhj.v18i1.57884